DESCRIPTION DIMENSIONS
“OVERCENTER” VALVE WITH INTERNAL PILOT OPERATION
OWC-...E/L...
OWC - *** E/L ***
“OVERCENTER”
Number of valves: double - D
single - S
Modification
TECHNICAL DATA
Pressure adjustment range 40...250 bar
Rated flow for all types 35 l/min
Pressure ratio P /P (work/pilot) for all types 4/1
W P
Working liquid-hydraulic oils with characteristics:
-viscosity 10...400 cSt
-degree of filtration 0,025 mm
o
-temperature -20...+80 C
ORDERING CODE
ORDERING CODE
ORDERING CODE
ORDERING CODE
“OVERCENTER” valves
with internal pilot operation
for pipe mounting-
OWC-...E/L...
The “OVERCENTER”
valves are designed to
control moving loads and to
prevent loads from running
ahead of pump. They lock
the load at any position
without drift and protect of
overloading and thermal
expansion by open
center control valves.
Connecting threads: G3/8 - 38
G1/2 - 12
OWC-DE/L...
OWC-SE/L...
SYMBOL
APPLICATIONS
OWC-DE/L...
OWC-SE/L...
Ø
Ø
130
95
4
4